Maintenance And Service - Milky FJ 50 PF Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

MAINTENANCE AND SERVICE

Troubleshooting
When a fault occurs, the information will be written on display and device will stop, if not
stop it yourself by main switch and disconnect it from main power supply. When device
malfunctions, disconnect the device from mains and call the authorized service - do not
repair it yourself!
In the chart below are most common errors and resolutions
Error code
Device will not start, the
information on display is:
"Water low level"
1
Device will not start; the
2
display is blank
Device worked, then it sud-
denly stopped heating.
3
Device worked, then it sud-
denly stopped heating.
4
"Error tmp. MILK" is shown
5
"Error tmp. WATER" is shown Heating water sensor is malfunction – authorized
6
40
Description
There is not enough heating water inside the
device, add water – see chapter water filling into
secondary coat.
Water level sensor may be malfunction – authori-
zed personnel may check for loosened contacts,
for inappropriate position or may replace the
sensor.
Check the main power supply
Check the main switch position
Check the safety stop button position
Authorized personnel may open electro case and
check the fuse state – see chapter with electric
case contents.
If the fuse is activated call authorized service to
check for electrical malfunctions.
Authorized personnel may open electro case and
check the thermostat state
– see chapter with electric case contents.
If the thermostat is activated the device has
overheated - call authorized service. The security
switch switched off all functions on the device.
(overheating protection).
Milk sensor is malfunction – authorized personnel
may check for loosened contacts or replace the
sensor.
personnel may check for loosened contacts or
replace the sensor.
Resolution