Procedure:
Step 1: On the baseplate, there are the holes for the installation.
Step 2: Hold the baseplate onto the location where the device is to be installed.
Step 3: Mark the boreholes with a pen or a suitable tool.
Step 4: Drill the holes.
Step 5: Hold the baseplate in the desired position and tighten it.
Before taking into operation for the first time, the installation has to be approved by an expert!

DMX-512 control

The wires must not come into contact with each other, otherwise
Only use a stereo shielded cable and 3-pin XLR-plugs and connectors in order to connect the controller with
the device or one device with another.
Occupation of the XLR-connection:
If you are using controllers with this occupation, you can connect the DMX-output of the controller directly
with the DMX-input of the first device in the DMX-chain. If you wish to connect DMX-controllers with other
XLR-outputs, you need to use adapter-cables.
Building a serial DMX-chain:
Connect the DMX-output of the first device in the DMX-chain with the DMX-input of the next device. Always
connect one output with the input of the next device until all devices are connected.
Caution: At the last device, the DMX-cable has to be terminated with a terminator. Solder a 120
between Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last device.

Addressing the device

Set the required DMX-address via the Control Board.

DANGER TO LIFE!

the devices will not work at all, or will not work properly.
To define the starting address, you have to be in DMX-mode. Press MODE until
the display indicates d001. In DMX-mode, the DMX LED indicator lights up.
Set an address between 001 and 512 via the UP and DOWN buttons.
16/36
resistor
70064175_V_1_1.DOC