Electric heater Aqua compact
Start
1. Fill water in the pool to the correct level.
2. Start the pump for the pool water circulation.
3. Check that the water circulates normally in the system and that all air is drained from the system.
The heater must be completely water-filled before switching on the power. The heater can only be switched on when all air is
drained out of the system.
4. Test the function of the heater by turning the thermostat dial back and forth and check that the thermostat's contactor
switches on and off.
The flow monitor is controlled by switching off the flow through the heater with a shut-off valve and checking that the
contactors switch off. Switch on the water again. The contactors should then turn on again.
5. Set the desired pool temperature with the thermostat knob.
6. The water is now heated to the desired temperature.
Operation
When backwashing and cleaning the filter, switch off the power of the heater. If there is a risk of freezing, the power must be
switched off and the heater must be emptied of all water.
General information
Ensure good operation and long life of the electric heater by following water quality limit values below.
Chlorine content:
max 3.5 mg/l (ppm)*
pH value:
7.2–7.6
Alkalinity:
60–120 mg/l (ppm)
Calcium hardness:
100–300 mg/l (ppm)
Iron:
max 0,1 mg/l (ppm)*
Copper:
max 0,2 mg/l (ppm)*
Manganese:
max 0,05 mg/l (ppm)*
Phosphorus:
max 0,01 mg/l (ppm)*
Nitrate:
max 50 mg/l (ppm)*
Incoloy
Chloride (salt) content: max 250 mg/l (ppm)
If the water quality limit values are not adhered to, the product warranty does not apply.
Troubleshooting
1. Check the fuses.
2. Check that the system has the required flow through the heater.
3. For safety reasons, the heater's overheating protection is triggered in the absence of water or poor circulation. This is the
most common reason why the heater has "stopped working". Check if the overheating protection has tripped and investigate
the cause. After the cause has been clarified and rectified, the overheating protection is restored by:
- Unscrewing the protective cap (A).
- Pressing the reset button (B) on the junction box.
- Put the cover back on.
4. Checking the heater function, see item 4 under "Start".
5. Adjusting the thermostat to a higher temperature.
6. If the problem persists: contact the installer.
Waste management and recycling
You must dispose of this product according to local laws and regulations.
Since this product contains electronic components, it must be disposed of separately from household waste.
When this product reaches the end of its life cycle, contact local authorities to find out more about waste management and
recycling.
Titanium
max 35 000 mg/l (ppm)
12
ENGLISH
* according to EN 16713-3
A
B
Surface treatment
Designed by:
Drawn by: Date
E
ASA 2019-07-15
The tolerance class in accordance with this
Assembly drawing no.
Art.no.
part of ISO 2768-1
Aqua Compact 3-18kW
Scale
(Elv plast)
Drawing number
Box 728, SE-194 27 Upplands Väsby, Sweden
Phone +46 8 59411050, Fax +46 8 59086880
Approved by:
14160X-03
Revised by: Date
ASA
Rev.no.
M13053 0