Electronic Trip Unit
Unité de protection électronique
Elektronische beveiligingsunit
Abbreviations Connection scheme:
---------------------------------------------------------------------
24V+/24V-: AUXILIARY POWER SUPPLY TO TRIP UNIT
N-RC:
NEUTRAL ROGOWSKI COIL
ZSI OUT:
ZONE SELECTIVE INTERLOCK OUT
ZSI IN:
ZONE SELECTIVE INTERLOCK IN
RXD:
MODBUS / Profibus COMMUNICATION
TXD:
MODBUS / Profibus COMMUNICATION
TX EN I
Profibus Communication
5V ISO
Profibus
ISO GND
Profibus
ELCT
Earth leg CT
RELAY O/P: RELAY OUT PUT
RELAY I/P:
RELAY IN PUT
V-A/V-B/V-C: SIGNAL INPUT FROM
VOLTAGE CONDITIONER (L1-L2-L3)
GND:
GROUND FOR VOLTAGE
note
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A31
A32
A36
A37
A38
24V+ 24V-
N-RC
N-RC
-
+
+24-
VDC
N
GT-H
Abréviations Schéma de connexion:
---------------------------------------------------------------------
24V+/24V-: ALIMENTATION AUXILIAIRE DE L'UNITÉ DE
PROTECTION
BR-N:
BOBINE DE ROGOWSKI NEUTRE
ISZ OUT:
INTERVERROUILLAGE SÉLECTIF PAR ZONE OUT
ISZ IN:
INTERVERROUILLAGE SÉLECTIF PAR ZONE IN
RXD:
COMMUNICATION MODBUS
TXD:
COMMUNICATION MODBUS
TX EN I
Communication Profibus
5V ISO
Profibus
ISO GND
Profibus
ELCT
Raccordement à la terre CT
S RELAIS:
SORTIE RELAIS
E RELAIS:
ENTRÉE RELAIS
V-A/V - B/V-C: ENTRÉE SIGNAL DU
conditionneur de signaux (L1, L2, L3)
TER:
TERRE POUR TENSION
notes | notities
A39
B1
B2
ELCT
Relay I/P
I
I
N
1
2
TU
Connection scheme |
Schéma de connexion Bedradingsschema
Signal Input from
Voltage Conditioner
V-C
V-B
V-A
L3
L2
L1
B39
B38
B37
Afkortingen Bedradingsschema:
---------------------------------------------------------------------
24V+/24V-: Hulpstroomtoevoer naar beveiligingsunit
N-RC:
ZSI OUT:
ZSI IN:
RXD:
TXD:
TX EN I
5V ISO
ISO GND
ELCT
RELAY O/P: Relais OUTPUT
RELAY I/P:
V-A/V - B/V-C: Signaalinput van
GND:
TRIP UNIT
EntelliGuard G
B3
B27
B28
B29
ZSI
ZSI
ZSI
I
OUT+
OUT-
IN+
com
+
-
+
ZSI
|
Communication
TX
RX
5V ISO
TX EN I
GND
5V
N
B36
B35
B34
B33
B32
Neutrale Rogowski-spoel
Zoneselectieve vergrendeling uit
Zoneselectieve vergrendeling uit
Modbus-communicatie
Modbus-communicatie
Profibus Communicatie
Profibus
Profibus
Earth leg CT
Relais INPUT
Voltageregulator (L1, L2, L3)
Grondstroom voor voltage
2
.7
B30
ZSI
IN-
-
ZSI
ISO
GND
B31
2-55