5.2.2. Mounting
Warning:
Make sure the supply voltage is correct (see rating plate).
Fit the connecting line such that it cannot suffer mechanical damage.
Earthing is needed to ensure a proper and safe operation.
Fit the anti-static bar with the emitter points towards the material to be discharged.
Mount the bar in such manner that the emitter points are not subject to mechanical damage.
Use the facilities specially fitted for mounting purposes.
Fit the connecting line to the (mains) voltage connection for the anti-static bar using
appropriate connectors and fix the cable securely to prevent mechanical damage.
Make sure that the equipment is properly earthed, by means of the (main) voltage
connection.
Fit a line-side fuse in the connecting line.
A neon lamp (230 V) can be fitted as high-voltage indicator between the signal wire and
earth, see Figure 1,2 or 3. Also a relay can be fitted which triggers an alarm signal if the high
voltage fails.
Connect the connecting line.
Figure 1: connection of the Neoprene power cord.
Figure 2: connection of the shielded (FLEX-SY-J2) power cord.
Figure 3: connection of the UL (SOOW) power cord.
P-SH-N-Ex_UM_9752031420_NL_D_GB_F_V2_0
The fuse should have a breaking capacity of
1500 A.
The breaking capacity is the maximum short
circuit current that the fuselink can safely
interrupt.