5.2.2. Mounting

Warning:
 Make sure the supply voltage is correct (see rating plate).
 Fit the connecting line such that it cannot suffer mechanical damage.
 Earthing is needed to ensure a proper and safe operation.
 Fit the anti-static bar with the emitter points towards the material to be discharged.
 Mount the bar in such manner that the emitter points are not subject to mechanical damage.
 Use the facilities specially fitted for mounting purposes.
 Fit the connecting line to the (mains) voltage connection for the anti-static bar using
appropriate connectors and fix the cable securely to prevent mechanical damage.
 Make sure that the equipment is properly earthed, by means of the (main) voltage
connection.
 Fit a line-side fuse in the connecting line.
 A neon lamp (230 V) can be fitted as high-voltage indicator between the signal wire and
earth, see Figure 1,2 or 3. Also a relay can be fitted which triggers an alarm signal if the high
voltage fails.
 Connect the connecting line.
Figure 1: connection of the Neoprene power cord.
Figure 2: connection of the shielded (FLEX-SY-J2) power cord.
Figure 3: connection of the UL (SOOW) power cord.
P-SH-N-Ex_UM_9752031420_NL_D_GB_F_V2_0
The fuse should have a breaking capacity of
1500 A.
The breaking capacity is the maximum short
circuit current that the fuselink can safely
interrupt.