Technical Specifications - Lincoln Electric POWER WAVE 455M Manuel D'utilisation

Masquer les pouces Voir aussi pour POWER WAVE 455M:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 46

Technical Specifications

POWER WAVE 455M CE & 455M/STT CE:
Input Voltage
400V ± 15%
Three Phase
Duty Cycle
(Based on a 10 min. period)
455M
All process except STT
455M/STT
STT process only
Welding Current Range
Maximum Open Circuit Voltage
Pulse Frequency
0.15-1000Hz
Pulse Voltage Range
Pulse and Background Time Range
100u sec.-3.3 sec.
Auxiliary Power
40Vdc @ 10A and 220Vac @ 5A
455M/STT only: STT Peak & Background Current
Fuse (delayed) or Circuit Breaker ("D" characteristic) Size
Height
663mm
Operating Temperature
-20°C to +40°C
For any maintenance or repair operations it is recommended to contact the nearest technical service center or Lincoln
Electric. Maintenance or repairs performed by unauthorized service centers or personnel will null and void the
manufacturers warranty.
Input Current at Rated Output
36A @ 100% Duty Cycle
RATED OUTPUT AT 40°C
100%
60%
100%
60%
100%
5-500Amps
75Vdc
5-55Vdc
15-450A
RECOMMENDED INPUT CABLE AND FUSE SIZES
40A
PHYSICAL DIMENSIONS
Width
505mm
INPUT
48A @ 60% Duty Cycle
Output Current
400A
500A
All process except STT
400A
500A
STT process only
325A
OUTPUT RANGE
Length
835mm
13
Frequency
50/60 Hertz (Hz)
Output Voltage
36Vdc
40Vdc
All process except STT
36Vdc
40Vdc
STT process only
33Vdc
Process Current Range
MIG / MAG
50-500A
FCAW
40-500A
SMAW
30-500A
Pulse
5-720A
455M/STT only: STT
40-325A
Input Power Cable
3 Conductors, 10mm2 (Line)
1 Conductor, 6mm2 (Ground)
455M: 114Kg
455M/STT: 121Kg
Storage Temperature
-40°C to +40°C
Weight

Publicité