Maintenance And Troubleshooting; Maintenance; Spare Parts; Failure Diagnosis - Erreka VIVO-D103 Manuel De L'installateur

Armoire de commande pour l'actionneur « izar »
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

MAINTENANCE AND TROUBLESHOOTING

1

MAINTENANCE

Disconnect the device from the power supply before carrying out any maintenance operation.
1 Frequently check the installation in order to detect
any imbalance or sign of deterioration or wear. Do
not use the device if any repair or adjustment is
necessary.
2

SPARE PARTS

If the control board needs repairing, go to an
authorised
assistance
manufacturer; never try to repair it yourself.
3

FAILURE DIAGNOSIS

F1 (0,8A)
Electr.
J8
J7
ANT.
DL16
L16
L17
DL17
J1
L6
DL6
STOP
DL10
DL8
ON
OFF
4
DL2
ST1
ST2
L1 L2
L3
L4
L5
DL1
GARAGE
ST1
ST2
FT
FCA FCC
DL3 DL4
DL5
Problem
The control board does not work
and no LED indicator comes on
centre
or
the
F5 (0,38A)
Periph.
J3
J2
J6
J5
J4
L11
L7
L12
K4
CLOSE
Lamp.
L10
L8
L13
L9
OFF
N
L
BATTERY
POWER
230Vac
12V
LIGHT
Cause
Main switch SW1 in "OFF"
Absence of control board power supply
Electronic fuse F1 blown
Transformer or board failed
2 Check that the operation and safety devices
(photocells or safety strips), as well as their
installation, have not suffered any damage from the
weather or external agents.
Use only original spare parts.
Diagnosis LEDs and fuses
SW1 General power switch
F1
Electronic fuse (0.8A)
F2
Transformer secondary fuse (10A)
F3
Motor fuse (10A)
F2 (10A)
F5
Peripheral fuse (0.38A)
Sec. Transf
DL1
ST1 Opening and closing key signal
(NA)
DL2
DL11
ST2 Closing key signal (NA)
DL3
Photocell signal (NC)
DL7
DL4
Opening limit switch signal (NC)
DL12
DL5
Closing limit switch signal (NC)
DL6
STOP signal (NC)
DL7
Flashing light relay
DL8
Door open
DL9
Garage light relay
DL13
DL10 Stop due to obstacle
DL9
DL11 Fast/slow operation relay
DL12 Closing relay
DL13 Opening relay
DL16 230V Power supply
DL17 Microcontroller supply
F3 (10A)
Motor
E181D
Solution
Place SW1 in "ON"
Restore the power supply
Replace F1 using another fuse of the same
value and investigate the cause of failure of
F1
Call the technical service
VIVO-D103 / ADB30 Control board
English
53

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Adb30

Table des Matières