FUSE CHECK/REPLACEMENT
1.
Disconnect the battery connector (12).
2.
Move aside the recovery water drain hose (16).
3.
Remove the battery charger cable (I, Fig. 10) from the holder (J).
4.
Remove the screws (A) and carefully move aside the panel (B) by disengaging the grommet (K) from its housing on the
panel (B).
5.
Check/replace the following fuses:
(C)F1 fuse, deck: (40 A)
(D)F2 fuse, vacuum system: (30 A)
(E)F3 fuse, drive system: (30 A)
(F)F4 fuse, signal circuits: (3 A)
(G)F5 fuse, brush/pad-holder release: (20 A)
(H)F6 fuse, pump: (3 A)
6.
Perform steps 1 to 4 in the reverse order.
9096910000(1)2006-09
A
F G H
A
A
J
I
Figure 10
INSTRUCTIONS FOR USE
A
B
D
E
C
K
S311324
27