The DOORRADMB is a high performance motion detection sensor specifically designed for the activation of automatic doors.
For the safe and accurate use of this product, please read this instruction manual carefully.
1

Technical specifications

Power supply :
DC 12~30V, AC 12~24V
Product Size : 120mm x 70mm x 41.5mm (W x L x H)
Microwave module :
24.125GHz
Hold time :
1.2 Sec.
Detecting field :
4m x 3m (W x D) (Height 2.2m)
2
General Information
Sensing Module
Sensor Body
LED
3
Installation Guide
Do not supply power during installation.
Do not disassemble or modify the device, it may cause fire or electric shock
1
2
Affix mounting template to
Attach the sensor body to the wall
transom and drill holes.
Tilt the sensing module angle
3
4
Connect power cable to the
Up • Down • Left • Right to change the
sensor body
detection area
4

Sensitivity Adjustment

Sensitivity is adjustable
by setting the volume on
the sensor body
Min.
Max.
5
Wiring Diagram
2 power wires & 2 relay contact wires.
6

Mounting Information

1
2
Avoid moving objects close
Avoid heavy rain and snow
to the sensor
3
4
Avoid vibration
Avoid fluorescent light sources
TAU S.r.l.
Via E. Fermi, 43 - 36066 Sandrigo (VI) Italy - Tel: +39 (0)444 750190 Fax: +39 (0)444 750376 www.tauitalia.com
Current consumption :
Contact capacity :
Max Install height :
Operating Temp/Humidity : -20°C~+60°C/0~90%
International Protection : IP54
Cover
Connector
Screw Hole
Cable Hole
NO
NC
< Default value : NO >
7
Detection Area Position Adjustment
Adjust the Sensing module up and down to achieve a detection area close to or far from the door.
Adjust the Sensing module to the right and left to achieve the desired side approach detection area.
DC 12~30V
8
(Gray)
AC 12~24V
Detection Field
(Yellow)
Output
m
9
Weather Cover
The specifications of this product can be changed without prior notice
< 1.4W
0.5A/125VAC, 1A/24VDC
4.0m
<Accessories>
Mounting Template
Cable
Screw
Instructions
Sensitivity volume
27°
41°
Sensing module
Sensing module
vertical angle
vertical angle
S0 : 27°
S2 : 41°
Left angle rotation : 15°(Max : 30°)
Front angle rotation : 0°
Right angle rotation : 15°(Max : 30°)
(Mounting Height : 2.2m)
m
Default
Sensitivity
Module
vertical angle
S0 :
0 Step(27°)
S1 :
1 Step(34°)
S2 :
2 Step(41°)
S4 :
4 Step(55°)
(sold separately)
MODEL: WCHR50