Switching on and off
Make sure that the power supply
voltage matches the voltage rating
indicated on the device's type plate.
Connect the machine to the power
supply.
Caution! Fold the protective
device (6) down before you
switch on the machine.
Switching on:
Press the on switch (2).
Switching off:
Press the off switch (1).
Emergency stop:
Press the emergency stop button (5).
After pressing the emergency stop
button, the emergency stop button
(5) must be activated again by
turning it. Press the on switch (2) to
restart the device.
Clamping the Workpieces
Only work on workpieces that can be secu-
rely clamped between the chuck jaws (24).
The workpiece must not yield too much.
Otherwise it is nor possible to apply ade-
quate tension.
The workpiece must not be too small or too
large either.
Removing Blockages
-
You should always select a suitable
feed rate which allows trouble-free chip
breaking.
34
-
If the bit is jammed in the workpiece,
turn off the power and unplug the po-
wer cord. Turn the bit on the drill chuck
anticlockwise with a little jerk to break
the chip and release the bit again.
-
If a fragment is produced during the
processing of the workpiece, turn off the
power and unplug the power cord. Use a
pair of pliers and remove the fragment to
prevent it flying off in an uncontrolled way.
Cleaning and
maintenance
Pull the mains plug before any ad-
justments, maintenance or repair.
Have any work on the device
that is not described in this in-
struction guide performed by
a professional. Only use ori-
ginal parts. Allow the device
to cool off before any mainte-
nance or cleaning is underta-
ken. There is a risk of burning!
Always check the device before using it
for obvious defects such as loose, worn or
damaged parts, correct the positioning of
screws or other parts. Exchange the dama-
ged parts.
Cleaning
Do not use any cleaning agents or
solvents. Chemical substances can
etch the plastic parts of the device.
Never clean the device under run-
ning water.
• Thoroughly clean the device after every
use.