Choose a suitable position and fix the mounting plate on the
ceiling with screws. Fasten the detector on the mounting plate in a
clockwise direction. It is suggested to mount it at the height of
2.5-5 meters from the ground.
Keep the detector away from air conditioner, electronic fan,
refrigerator, oven, heater or any other objects which will cause fast
temperature changing.
Avoid mounting it under direct sunlight or any objects blocking the
lens, so as not to influence the detection effect.
Testing (Walk Test)
After installation, power on the detector. After self-testing for
1 minute, press the test button, walk in the scope by crossing the
infrared spectrum (see below diagram), and watch the LED indicator
to make sure it is working. The LED indicator will flash once when
body movement is detected.
Low detection sensitivity
Connect with the Control Panel
When the control panel is in connecting state, press the test button
twice to send wireless signal. One beep is heard after panel receives
signal, which means of successful connection.
Arm the system, and trigger the detector again. The panel will
alarm immediately. This indicates the detector has been successfully
connected with the panel.