EN
Infrared sensor:
Detecting human body's infrared spectrum. Don't
touch the surface by hand and keep it clean.
LED Indication
The LED indicator can be turned on or off by setting jumpers. See
"PCB Layout" above.
Flash continuously:
Under self-testing state
Flash once:
Intruder is detected
Flash twice:
Test mode is finished, enters into the power saving
mode.
Flash once every 3 seconds:
batteries immediately.
Detection Range
3.6 m
Low battery, please change the
Side View
6 m
Top View
Usage
Remove the battery activation strip to activate batteries. It will enter
working state after one-minute's self-testing.
Working Mode
Testing Mode:
Press test button, the sensor enters into the testing
mode and detects once every 10 seconds. After 3 minutes, the LED
flashes twice, and the sensor enters into the power saving mode.
Power-Saving Mode:
In working state, if the sensor is triggered
twice within 3 minutes, it will enter sleeping mode to save power.
After no movement within next 3 minutes, the sensor goes back to
the working state.