Disposal
This product is not permitted to be disposed of with household waste.
This is indicated by with the adjacent icon.
You can return this product to Dräger free of charge. For information
please contact the national marketing organisations and Dräger.
Batteries and rechargeable batteries are not permitted to be disposed
of as household waste. This is indicated by the adjacent icon. Dispose
of batteries and rechargeable batteries as specified by the applicable
regulations and dispose of at battery collection centres.

Technical Data

Excerpt see the Technical Handbook for details
Ambient conditions:
During operation and
-20 to +50 °C with NiMH power pack types:
storage
HBT 0000 and HBT 0100,
alkaline single cell type:
Duracell Procell MN 1500
-20 to +40 °C for NiMH single cell type:
GP 180AAHC
Panasonic LR6 Powerline
0 to +40 °C for alkali single cell types:
Varta 4006
700 to 1300 hPa
10 to 90 % (up to 95 % short-term) rel. hum.
Temperature range over
-40 to +50 °C
2)
a short period
:
Maximum of 15 minutes with NiMH power pack T4
(HBT 0000) or T4 HC (HBT 0100)Requirement:
storage of the instrument at room temperature
(+20 °C) for at least 60 minutes in advance.
1)
.
2)
2)
and alkaline single cell type:
2)
2)
, Varta 4106
,
Position of use
any
Storage time
X-am 5600
1 year
Sensors
1 year
Electrical classification
IP 67 for instrument with sensors
Alarm volume
Typically 90 dB (A) at 30 cm distance
Operating time
– Alkali battery /
NiMH single cells
Typically 9 hours under normal conditions
(Battery holder
ABT 0100 (X-am 5600))
– NiMH-
power pack:
T4
(HBT 0000)
Typically 9 hours under normal conditions
T4 HC (HBT 0100)
Typically 10.5 hours under normal conditions
Dimensions
approx. 130 x 48 x 44 mm (H x W x D)
Weight
approx. 220 to 250 g
Refresh interval for
1 s
display and signals
CE marking:
See declaration of conformity on page 348.
3)
Approvals:
See "Notes on Approval" on page 347.
The BVS 10 ATEX E 080 X technical suitability test
is based on the adjustment with the target gas.
1)
The Technical Handbook and Instructions for Use / data sheets for the utilized sensors and the
Dräger PC software CC Vision for Dräger X-am 5600 can be downloaded on the product page
of the X-am 5600 at the following Internet site: www.draeger.com
See also the instructions for use provided and the data sheets for the sensors used.
2)
Not part of the BVS10 ATEX E 080X and PFG 10 G 001X technical suitability test.
3)
The technical suitability tests are valid for the X-am 5600 gas detection instrument and the
calibration cradle. The explosion-protection approvals are only valid for the X-am 5600 gas
detection instrument; the calibration cradle must not be used in the Ex zone.