Contrôleur À Minuterie Dct1000 Pour Collecteur De Poussière - Eco blast DCM 3000 Série Manuel D'instructions Et Pièces Détachées

Table des Matières

Publicité

CONTRÔLEUR À MINUTERIE DCT1000 POUR COLLECTEUR DE POUSSIÈRE
E-97 DCT iom
12/29/04
Thank you for purchasing the DCT1000 Dust Collector Timer
Controller. You have selected a state of the art dust collector timer
control that will provide years of dependable operation and service.
The DCT1000 Dust Collector Timer Controller was designed to be
used with pulse-jet type dust collectors for on-demand or continu-
ous cleaning applications.
Continuous cleaning applications do not require external inputs and
can be used for time based "on-demand" cleaning through use of
the cycle delay feature.
For on-demand applications, the plug-in pressure modules
(DCP100A/200A) can be used to take full advantage of all the fea-
tures the DCT1000 offers, or an external pressure switch (such as
the Dwyer Photohelic
As with traditional Dwyer products, the Dwyer DCT1000 was
designed so that it is easy to use, thus allowing for a quick and easy
start up for your dust control applications. The contents inside this
installation and operating manual will guide you through the features
of the DCT1000 and how they can be applied to get the most out
of your dust control requirements.
DWYER INSTRUMENTS, INC.
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, U.S.A.
04-30-2012
Innovation et technologie de pointe
8:55 AM
Page 1
Series DCT1000 Dust Collector Timer Controller
Specifications – Installation and Operating Instructions
) can be used for High/Low limit control.
®
Dépoussiéreurs DCM3000 à 50000 - Manuel d'instruction
SPECIFICATIONS
DCT1000 Timer Controller:
Output Channels: 6, 10, & 22 channels. Expandable to 255
channels using DCT1122 & DCT1110 channel expander boards.
Power Requirements: 85 to 270 VAC, 50 or 60 Hz.
Solenoid Supply: 3A maximum per channel.
Fuse: 3A @ 250 VAC. Low voltage control circuitry is isolated from
the line voltage for system safety.
Temperature Limits: -40 to 140°F (-40 to 60°C).
Storage Temperature Limits: -40 to 176°F (-40 to 80°C).
On Time: 10 msec to 600 msec, 10 msec steps.
On Time Accuracy: ±10 msec.
Off Time: 1 second to 255 seconds, 1 second steps.
Off Time Accuracy: ±1% of the value or ±50 msec, whichever is
greater.
Weight: 1 lb 3.0 oz (538.6 g).
Agency Approvals: UL, cUL.
Phone: 219/879-8000
www.dwyer-inst.com
Fax: 219/872-9057
e-mail: info@dwyer-inst.com