When the equipment is switched on, it
shows the status it was in when it was
previously switched off.
3.1.1.2
The [SET]key
By means of this key it is possible to:
Confirm set choices or values.
3.1.1.3
The [UP]key
By means of this key it is possible to:
Scroll up the list of the various parameters;
Increase the value of a parameter.
3.1.1.4
The [DOWN]key
By means of this key it is possible to:
Scroll down the list of the various parameters;
Reduce the value of a parameter.
3.1.1.5
The Interface Display
The interface display (Fig. 2) makes it possible to
visualise:
Regulation temperatures;
Alarm/Error codes;
Status messages;
Operating parameters.
Fig. 2 – User interface display
Compressor
If this is lit: the compressor is
LED
active.
It this is flashing:
Defrosting LED
If this is lit: defrosting is in
progress
MF LED
If this is lit: the electric heating
element is on
Fan LED
If this is lit: the fan is active
Maintenance
If this is lit: maintenance of the
LED
air filter is required (if present)
Alarm LED
If this is lit: check the list of
alarms
procedure indicated in this
manual
Degree
If
Celsius LED
measurement
The compressor switching
on
procedure
is
in
progress.
The modification of the
operating set points is in
progress;
and
follow
the
this
is
lit:
the
unit
of
for
temperatures is the degree
Celsius
Degree
If
Fahrenheit LED
measurement
temperatures is the degree
Fahrenheit.
On/stand-by
If this is lit: the equipment is in
LED
the stand-by status.
If it is flashing, the equipment
has
manually during a switching
on/off period in a certain
timeslot.
Not used
If the equipment is in the "ON" status, during
normal operation, the display will show the
established temperature by means of parameter
P5:
If P5 = 0, the display will show the temperature
of the upper part of the boiler;
If P5 = 1, the display will show the active
working set point;
If P5 = 2, the display will show the temperature
of the lower part of the boiler;
If P5 = 3, the display will show the temperature
of the evaporator;
If the equipment is in the "stand-by" status,
the display will be switched off.
To change the P5 parameter, refer to the
installation manual.
3.1.1.6
Warnings
Loc
The keyboard is locked.
dEFr
The defrosting procedure is in progress and it is
not possible to enable other functions
Anti
The "Anti-Legionella" function is in progress.
ObSt
The "Overboost" function is in progress.
ECO
The "Economy" function is in progress.
Auto
The "Automatic" function is in progress.
3.1.2

Operating logic

3.1.2.1
Operating modes
The equipment foresees the following operating
modes:
AUTOMATIC operating mode
This mode mainly uses the renewable energy
of the heat pump as a support measure, the
electric heating elements can be enabled;
these latter heating sources are enabled if the
water temperature is below a certain level, or
this
is
lit:
The
unit
of
for
been
switched
on/off
pag. 5 / 14