Dometic 5 Série Instructions De Montage page 18

Réfrigérateur à absorption
Masquer les pouces Voir aussi pour 5 Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installing the refrigerator
6.3
Creating the air vents
I
NOTE
At high ambient temperatures, the refrigerator can only provide its
maximum cooling capacity if the optimum ventilation has been
provided.
➤ Make an air inlet vent and an air outlet vent in the outer wall. Observe instructions
when doing this, see chapter "Preparing the installation" on page 16 and the
dimensions in fig. 7 and fig. 8, page 5.
If the ventilation grille of the air inlet vent cannot be installed flush with the floor of the
niche, you need to install an inlet vent in the floor:
➤ Make an air inlet vent in the floor (fig. 5, page 4) behind the refrigerator near the
gas burner. The vent pipe must lead directly outside. This allows leaking
unburned gas to escape outside.
➤ Shield the end of the opening with a deflector to prevent sludge or dirt from get-
ting inside while driving (fig. 5, page 4).
6.4
Installing the ventilation grille
LS200
No. in
fig. 7, page 5
1
2
3
18
Description
Installation frame
Ventilation grille
Winter cover
RMV5301, RMV5305
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Rmv5301Rmv5305