Selection Of The Operating Mode - Lenze E82MV Série Instructions De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6
Commissioning

Selection of the operating mode

6.2
Selection of the operating mode
Via the mode of operation you select the control mode of the controller. You can choose
between
V/f characteristic control
ƒ
Vector control
ƒ
Sensorless torque control
ƒ
The V/f characteristic control is the classical mode of operation for standard applications.
In comparison to the V/f characteristic control, with the vector control you obtain
improved drive characteristics by:
A higher torque throughout the entire speed range
ƒ
A higher speed accuracy and a higher concentricity factor
ƒ
A higher efficiency
ƒ
M
M
N
98

n
N

V/f characteristic control
Vector control
l
n
8200vec524
EDK82MV752 DE/EN/FR 7.2

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

E82mv302E82mv402E82mv552E82mv752

Table des Matières