4.1.1
Wiring according to EMC (CE−typical drive system)
Conditions for trouble−free operation:
Except for the mains cable, use shielded cables only.
ƒ
The shield must be carefully connected to PE (see below).
ƒ
Connect motor and mains PE conductors to separate PE terminals.
ƒ
A
B
X1
F
D
X2
E
E
0
Connecting cable for
l
Relay (for device version 001 or 151) or
l
electronic switching output (in case of device versions
152)
1
Mains cables L1, L2, L3, PE (loop through 2 cables to the
mains)
2
PE connection for mains cables
3
Shielded control cables; fix the shield tightly to the sheet
with the cable tie
4
Shielded control cables
5
Isolated terminal (e.g. star point for star connected
motor)
6
PE connection of the motor cable
7
Bus−I/O function module in slot 1
8
Fieldbus function module in slot 2
9
FIF support
EDK82MV752 DE/EN/FR 7.2
Wiring according to EMC (CE−typical drive system)
Shield connection:
1. Prepare the cable
B
2. Insert the cable tie
C
3. Lay the cable into
the cable tie and
tighten it. The
shield must be
G
tightly connected
to the shield
sheet.
E
82mot395
l
Mechanical installation
motec with motor or geared motor
X1
Terminal strip mains connection
X2
Terminal strip motor connection
PES HF shield connection by large surface connection to PE
4
I
J
H
82mot396
81