6
Commissioning
Important controller codes
Code
Possible settings
No.
Name
Lenze
C0517*
User menu
v
1 Memory 1
2 Memory 2
3 Memory 3
4 Memory 4
5 Memory 5
6 Memory 6
7 Memory 7
8 Memory 8
9 Memory 9
10 Memory 10
C0608* Fan monitoring
112
Selection
50
C0050
Output frequency (MCTRL1−NOUT)
34
C0034
Range of analog setpoint selection
7
C0007
Fixed configuration of digital input signals
10
C0010
Minimum output frequency
11
C0011
Maximum output frequency
12
C0012
Acceleration time main setpoint
13
C0013
Deceleration time main setpoint
15
C0015
V/f rated frequency
16
C0016
V
boost
min
2
C0002
Parameter set transfer
Possible entries for C0517
xxxx
All codes apart from the codes labelled
with "(A)".
0
0
Inactive
1
TRIP error message
2
Warning
l
IMPORTANT
After mains switching or in the g
l
function the code from C0517/1 is
displayed.
l
In the Lenze setting the user menu
contains the most important
codes for commissioning the
operating mode "V/f characteristic
control with a linear
characteristic"
l
If the password protection is
active, only the codes entered in
C0517 can be freely accessed
l
If less than 10 codes are required,
assign the value "0" (zero) to the
memory locations not used. Please
observe that the software
automatically assigns code C0050
to a memory location that is not
used, if it has not been explicitly
assigned to another memory
location.
Syntax:
Codes: C0517/x = cccc
Subcodes: C0517/x = cccc.ss
8200 motec 3 ... 7.5 kW:
Function must be activated during
commissioning (recommended:
C0608 = 1)! Otherwise, the controller
may be destroyed due to overheating.
For all other controllers:
It is essential to set C0608 = 0.
EDK82MV752 DE/EN/FR 7.2