Dimensions And Weights - Sulzer XRW 750 Instructions De Montage Et D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
Installation and Operating Instructions (Translation of Original Instructions)
XRW 750
1
General
The main parts of the installation and operating instructions with part no. 15972513-EU (Submersible Mixer Type XRW) are also valid for
XRW 7511. This also applies if the XRW 7511 model Ex is connected correctly and operated in safe mode. The same applies for the Safety
instructions. These are included in the separate booklet 15970799 and have to be studied carefully before installation and commissioning!
These "additional" installation and operating instructions for submersible mixer type XRW 7511 contain only cross-references
e.g. the differing, additional and product specific information.
1.1 - 1.3
Introduction; Correct usage of the product; Application restrictions
See chapter 1.1 - 1.3 of the Installation and Operating Instructions 15972513-EU.
1.4
Application areas
The submersible mixer XRW 7511 is used for mixing, stirring and agitating of viscous fluids containing solids in sewage treatment plants,
industry, and agriculture. It is specifically designed for the major mixing fuctions during homogenization of sludge and coenzymes.
1.5
Identification code
See chapter 1.5 of the Installation and Operating Instructions 15972513-EU. *Propeller type = 2-blade special propeller for sludge and
coenzymes.
1.6
Technical data
See chapter 2 of the Installation and Operating Instructions 15972513-EU.
1.6.1
Technical data XRW 7511, 50 Hz
[mm]
[1/min]
XRW 7511
750
296
1.6.2
Technical data XRW 7511, 60 Hz
XRW 7511
750
296
P
= Power input ; P
= Power output.
1
2
● = Standard ; ○ = Option; ●* =Moisture ingress monitor in connection chamber instead of oil chamber. Cable type: 10 m cable with free ends as standard
1.7

Dimensions and weights

See chapter 2 of the Installation and Operating Instructions 15972513-EU.
1.7.1
Dimensions XRW 7511
1187
[46,7]
EN 1585-A
[kW]
PA 150/4
16.3
1
PA 130/4
14.0
2
Propeller speed with gear ratio i=5;
1
1275,5
[50,2]
543
min.190
[21,4]
[min.7,5]
Figure 1 Dimensions XRW 750
[kW]
[A]
15.0
29.9
13.0
21.8
Propeller speed with gear ratio i=6
2
1187
[46,7]
[A]
259
●*
189
100x100
542,6
[4,0x4,0]
21,4
101,5
[4,0]
[kg/lb]
390/446
390/446
750
[29,5DIA]
5