Additional functions with ECC function controller (Ethernet):
– Automatic thermal disinfection according to DVGW work sheet W 551 as well
as safety switch-off
– Cleaning system shut-down
6.

Technical Specifications

Minimum flow pressure:
Recommended operating
pressure:
Maximum operating pressure:
Calculation flow rate:
Volumetric flow:
Operating voltage:
Power consumption:
Communication:
Type of protection:
7.

Scope of Delivery

8.

Installation Example

9.

Assembly Instructions

9.1
Make the connection for the gauging water.
Check the direction of flow.
9.2
Flush the pipes in compliance with DIN 1988.
x: not included in scope of delivery
9.3
Remove the flush connector.
x: not included in scope of delivery
9.4
Insert the solenoid valve with the seals.
Check the direction of flow.
9.5
Install a switch box (not included in scope of delivery ) at a height of
approx. 1200 mm.
9.6
Install a conduit (not included in scope of delivery ) leading to the switch box.
To protect the tiles, use masking tape when marking and drilling.
1.0 bar
1–5 bar
10 bar
0.2 l/s
0.50 l/s at a flow pressure of 3 bar
24 V DC
7 W
Ethernet via ECC function controller
Electronic IP 68, solenoid valve IP 40