Additional functions with ECC function controller (Ethernet):
– Automatic thermal disinfection according to DVGW work sheet W 551 as well
as safety switch-off
– Cleaning system shut-down
6.
Technical Specifications
Minimum flow pressure:
Recommended operating
pressure:
Maximum operating pressure:
Calculation flow rate:
Volumetric flow:
Operating voltage:
Power consumption:
Communication:
Type of protection:
7.
Scope of Delivery
8.
Installation Example
9.
Assembly Instructions
9.1
Make the connection for the gauging water.
☞
Check the direction of flow.
9.2
Flush the pipes in compliance with DIN 1988.
x: not included in scope of delivery
9.3
Remove the flush connector.
x: not included in scope of delivery
9.4
Insert the solenoid valve with the seals.
☞
Check the direction of flow.
9.5
Install a switch box (not included in scope of delivery ) at a height of
approx. 1200 mm.
9.6
Install a conduit (not included in scope of delivery ) leading to the switch box.
☞
To protect the tiles, use masking tape when marking and drilling.
1.0 bar
1–5 bar
10 bar
0.2 l/s
0.50 l/s at a flow pressure of 3 bar
24 V DC
7 W
Ethernet via ECC function controller
Electronic IP 68, solenoid valve IP 40
5