WIKA TSD-30 Mode D'emploi page 10

Masquer les pouces Voir aussi pour TSD-30:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3. Specifications
IO-Link, revision 1.1 (option)
IO-Link is optionally available for all output signals.
With the IO-Link option, switching output SP1 is always PNP
EN
Switching thresholds
Switch point 1 and switch point 2 are individually adjustable
Switching functions
Normally open, normally closed, window, hysteresis freely adjustable
Switching voltage
Power supply - 1 V
Switching current
without IO-Link: max. 250 mA
with IO-Link:
Adjustment accuracy
≤ 0.5 % of span
Temperature offset adjustment
±3 % of span
Scaling
Zero point: 0 ... 25 % of span
Full scale: 75 ... 100 % of span
Load
Analogue signal 4 ... 20 mA:
Analogue signal DC 0 ... 10 V: > 10 kΩ
Service life
100 million switching cycles
10
SP1 max. 100 mA, SP2 max. 250 mA
≤ 0.5 kΩ
WIKA operating instructions temperature switch, model TSD-30

Publicité

Table des Matières
loading