Electrical Requirements; Water Supply Requirements - Thermador T42BR810NS Instructions D'installation

Masquer les pouces Voir aussi pour T42BR810NS:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

80" - 90"
(203-229 cm)
¹⁄₂
83
" (212.1 cm) min.
³⁄₄
84
" (215 cm) max.
to bottom of solid soffit
(see chart following)
6"
(15.2 cm)
24"
(60.96 cm) min.
Model Width A (as shown above)
36
35¹⁄₂" (90.2 cm) to 35³⁄₄" (90.8 cm)
42
41¹⁄₂" (105.4 cm) to 41³⁄₄" (106.1 cm)
48
47¹⁄₂" (120.7 cm) to 47³⁄₄" (121.3 cm)
NOTE: Flooring under refrigerator must be at same level as the
room. Face of cabinetry must be plumb.
B
Dimension
77"
(196 cm)
A
Width
6"
(15.2 cm)
1"
(2.54 cm)
6"
(15.2 cm)
Dimension B
(as shown
above)
4" (10.2 cm)
10" (25.4 cm)
16" (40.6 cm)

Electrical Requirements

WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Before you move your refrigerator into its final location, it is
important to make sure you have the proper electrical
connection.
Recommended Grounding Method
A 115 volt, 60 Hz., AC only, 15- or 20-amp fused, grounded
electrical supply is required. It is recommended that a separate
circuit serving only your refrigerator be provided. Use an outlet
that cannot be turned off by a switch. Do not use an
extension cord.
IMPORTANT: If this product is connected to a GFCI (Ground
Fault Circuit Interrupter) protected outlet, nuisance tripping of the
power supply may occur, resulting in loss of cooling. Food quality
and flavor may be affected. If nuisance tripping has occurred,
and if the condition of the food appears poor, dispose of it.
NOTE: Before performing any type of installation, cleaning, or
removing a light bulb, remove the top grille and turn the master
power switch to OFF or disconnect power at the circuit breaker
box.
When you are finished, turn ON the master power switch or
reconnect power at the circuit breaker box. Then reset the control
to the desired setting.

Water Supply Requirements

All installations must meet local plumbing code requirements.
The water shutoff should be located in the base cabinet on
either side of the refrigerator or some other easily accessible
area. The right-hand side is recommended. The access hole
through the cabinet must be within ¹⁄₂" (12.7 mm) of the rear
wall.
NOTE: If the water shutoff valve is in the back wall behind the
refrigerator, it must be at an angle so that the tube is not
kinked when the refrigerator is pushed into its final location.