Safety Instructions EP 300 / EP 400:
Non-compliance with the safety instructions can result in danger both to persons and to the
environment and the
to the loss of any claims for damages. The operator
the contents of the Operating Instructions, particularly the Safety Instructions are known to
the operating personal.
If the equipment is not being used, stop the electric gear pump.
-
Do not let the pump run for longer than 5 minutes against a closed gun.
-
-
Be aware that this will heat up the pump.
The equipment must not be operated in potentially explosive areas.
-
-
Media in Hazardous Materials Class A1 and A2 must not be pumped.
Make sure that the 220V safety socket is protected by a fuse of at least 10A rating..
-
Before undertaking any repair or maintenance work shut off the power supply (pull out the mains
-
plug) and depressurise the equipment.
Make a regular check on the pressurised components (pressure hose and oil filler gun) and also
-
on the live parts of the pump for possible damage. Defective parts must be replaced with genuine
spares without delay.
Only use original accessories approved by MATO. No liability can be accepted for accidents
-
caused by components from other sources.
The operational safety of the equipment is only guaranteed if used in accordance with the
-
directions.
Maintenance, inspection and repairs must only be carried out by qualified specialist personnel,
-
who have acquainted themselves with the subject by studying the operating instructions.
Technical Data:
Voltage type
Enclosure class
Motor rating
Supply fuse
Max. Delivery
Suction head
Max Delivery pressure
viscosity)
Dimensions
Weight
(Pump & motor unit without accessories)
Pumped media EP 300 / EP 400 / EP 400-DS:
Mineral based oils and biologically degradable oils.
Media including hazardous materials Class A3 may be pumped.
Media to hazardous materials Class A1 and A2 must not be pumped.
If media not listed here are to be used, we request you to clear this with our technical department.
If oils (especially waste oils) are pumped which contain a high proportion of abrasive particles(metal
wear particles, grinding dust etc.), a fine filter must be fitted into the pump suction line.
Not suitable for water, chemicals or corrosive media.
8
equipment. Non-compliance with the safety instructions can lead
Type
(SAE 30 free outflow)
(depends on the oil
L x B x H
of the equipment must ensure that
EP 300
230V / 50 Hz
IP 55
0,37 KW
ca. 25 l/min
self priming up to 2.5m
8 bar
320 x 170 x 160 mm
9 kg
EP 400 / EP 400-DS
0,75 KW
10 A
16 bar
380 x 160 x 300 mm
12,5 kg