functionAl descriPtion
DMS800 MANUAL
Submenu
Function
ENCRYPTION
Activate the encryption function
When the encryption function is activated, the receiver
calculates a one-off key every time a transmitter is
synchronised. This key is sent to the transmitter during
the synchronisation process. The key is not displayed
and it is not possible to send the same key to two
transmitters.
Note:
For transmitters with firmware versions lower than 2.0,
choose the 32‑Bit encryption. (These transmitters do
not function with 512 Bit encryption.)
For transmitters with firmware version 2.0 or higher you
can achieve the highest possible security with 512 Bit
encryption.
If you use a replacement transmitter for a channel, the
encryption must be deactivated.
MUTE
The MUTE LOCK function deactivates the MUTE
switch on the transmitter
The transmitter synchronised with the receiver cannot
be muted with the MUTE button.
The MUTE=POWER function allows the MUTE button
of the transmitter to be used as the on/off switch as
well.
SYNCHR.
Programming the transmitter to the receiver settings
TRANSMITTER
GAIN
Set input level of the DSP chain
106