FOR YOUR SAFETY

Working safely with this machine is
possible only when the operating
and safety information are read
completely and the instructions con-
tained therein are strictly followed.
Before using for the first time, ask for
a practical demonstration.
Before working on the machine itself,
pull the mains plug.
Be careful of hidden electrical lines or gas
and water pipes. Check the working area,
e. g., with a metal detector.
Before commencing work consult the
responsible structural engineers, architects
or site supervision about any planned
borings, especially when cutting through
reinforcing steel.
Never use the machine without the PRCD
(GFCI) provided with the machine.
Always test the PRCD (GFCI) before start-
ing work, unless the PRCD (GFCI) is a
selftesting type.
The machine may only be operated using
a power supply with protection earthing
according to the regulations.
Never use the tool without the separating
transformer delivered with the tool or of the
type as specified in these instructions.
Replacement of the power cord or plug
should always be carried out by the manu-
facturer or a qualified service facility.
Keep liquid clear of parts of the tool and
away from persons in the working area.
The machine may not be operated by per-
sons under the age of 16 years.
The drill stand must always be mounted
firmly and must not be able to move during
drilling.
Only mount the drill stand on an even,
firm and smooth surface using the vacuum
pump.
When carrying out "over" head wet cut
core drilling, a water collecting ring and
RODIA
®
130/164/300
20
water suction are always to be used.
These must be in perfect condition.
When drilling "over" head always
secure the drill stand with the assembly.
Prevent the drilling core from falling.

Vacuum pump

Avoid any constrictions in the suction hose,
e.g. due to dirt accumulation, squeezing,
bending or stretching.
Check the suction hose each time before
use. Renew any leaking or damaged
parts.
Keep the cooling air vents on the pump
free and clean.
The underlying surface of the drill stand
must be clean, firm, smooth, dry and
without any holes. For further safety regula-
tions, see the operating instructions for the
drill stand.
Caution: The machine automatically
switches on immediately after inserting the
plug in the mains and becomes hot after a
long period of use.
Always connect the core drill and the
vacuum pump to the same power outlet.
Do not carry out any changes or modifica-
tions to the machine.
Should the machine have an operational
fault, the vacuum function will remain for a
short time. The cohesion is depe dent upon
the underlying surface and seal retention.
Stop working immediately and remove the
drill stand completely.
Use only original Rodia parts and
accessories.