5. The appliance must be installed 2. 3m above floor. (fig. 2).
6. The appliance shall not be installed in the laundry.
7. Before obtaining access to terminals, all supply circuits must be
disconnected.
8. The enclosure of the appliance shall be marked by word, or by symbols,
with the direction of the fluid flow (fIig. 3).
9. For electrical work, follow the local national wiring standard, regulation
and this installation instructions. An independent circuit and single outlet
must be used.
If electrical circuit capacity is not enough or defect in electrical work, it will
cause electrical shock fire.
10. Use the specified cable and connect tightly and clamp the cable so that no
external force will be acted on the terminal.
If connection or fixing is not perfect, it will cause heat-up or fire at the
connection.
11. Wiring routing must be properly arranged so that control board cover is
fixed properly.
If control board cover is not fixed perfectly, it will cause heat-up at connection
point of terminal, fire or electrical shock.
12. If the supply cord is damaged, it must be replaced by the manufacture or its
service agent or a similarly qualified person in order to avoid a hazard.
13. An all-pole disconnection switch having a contact separation of at least
3mm in all poles should be connected in fixed wiring.
14. When carrying out piping connection, take care not to let air substances go
into refrigeration cycle.
Otherwise, it will cause lower capacity, abnormal high pressure in the
refrigeration cycle.
15. Do not modify the length of the power supply cord or use of extension
cord, and do not share the single outlet with other electrical appliances.
Otherwise, it will cause fire or electrical shock.
16. If the water leaks during installation, ventilate the area immediately.
17. After completing the installation work, check that the water does not leak.
EN - 7