Technical Specifications - Toolland TC80100 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 7
TC 80100
standards need to be complied with when
installing the appliance.
The installation of the smoke outlet must
be as vertical as possible, avoiding the
use of joints, angles and deviations.
If the installation is connected to a
masonry chimney pipe we recommend
the tubes reach the exterior exit. If the
smoke outlet is via tubing only at least
three meters of vertical tubing are
recommended.
Important: the installation of this stove
must be carried out by a qualified
professional.
The ventilation opening must never be
obstructed.
Important: the woodstove must be
installed in a well ventilated place.
It is advisable to have at least one
window in the same room as the stove
which can be opened.
The tube connections should be sealed
with a refractory putty to prevent soot
from falling through the joints.
Do not position the stove near
combustible walls. The stove should be
installed on a non combustible floor
surface, if not a metal plate covering the
bottom surface area of the stove must be
placed underneath it and extend further
than 15 cm at the sides and 30 cm at the
front.
Whilst the stove is in use remove any
material nearby which could damaged by
the heat: furniture, curtains, paper,
clothes...
Please consider keep ease of access for
the cleaning of the product, smoke outlet
and chimney smoke outlet.
If you intend to install your stove near an
inflammable wall we advise you to leave
a minimum distance to facilitate cleaning.
This stove is not suitable for installation
in any chimney system shared by other
sources.
The stove should be installed on flooring
with adequate support.
If your current floor does not comply with
this criterion, it should be adapted with
appropriate measures (for example a
weight distribution plate).
FUEL
Use only dry wood with a maximum
moisture content of 20%.
Toolland | www.toolland.be
Wood with a moister content higher than
50 or 60% does not heat and combusts
very badly, and creates a lot of tar,
releases excessive amounts of vapour
and deposits excess sediments onto the
stove, glass and smoke outlet.
The fire should be lit using special fire
lighters, or paper and small pieces of
wood.
Never try to light the fire using alcohol or
similar products.
Do not burn plastic materials or greasy
products that can pollute the
environment and lead to risks of fire due
to obstruction of the pipes.

TECHNICAL SPECIFICATIONS

capacity
steel thickness
total height
smoke outlet diameter
weight
heat resistant paint
dimensions:
upper chamber
lower chamber
MAINTENANCE
Never clean the stove while it is in use.
It is also important to clean the smoke
outlet tubing periodically and check there
are no blockages before relighting fuel
after a long period of non-use.
At the start of each season a professional
should carry out a revision of the
installation.
In the event of a fire in the smoke outlet,
close all air draughts if possible and
contact the authorities immediately.
Any replacement parts which you may
need must be recommended by us.
WARRANTY
Refer to the enclosed guarantee conditions
for the terms and conditions of guarantee.
ENVIRONMENT
Should your device need replacement after
extended use, do not put it in the domestic
125 m²
1.5 mm
70 cm
12 cm
42 kg
800 °C
50.5 x 20 x 20 cm
61.5 x 30 x 30.5 cm
3

Publicité

Table des Matières
loading

Table des Matières