Troubleshooting; Wiring Diagram - Lofrans THETIS 5003 Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

THETIS 5003

6 TROUBLESHOOTING

FAULT
CAUSE
CORRECTIVE ACTION
Check the sensor electric connections.
Check if sensor operates properly.
Though UP or DOWN keys
If not, replace it.
are pressed, the instrument
doesn't receive any signal from
Check the position of sensor and magnet on gypsy
the magnetic sensor for more
and their distance.
V=11.6 Vdc
than 5 seconds.
Check the operation of electric
installation or anchor windlass.
The instrument's power
Verify the battery charge or
supply voltage is lower than10Vdc.
operation of the electricssystem.
V= 7.9 Vdc

7 WIRING DIAGRAM

12