Initial Start-Up; Troubleshooting - Hornbach KSI 8 Instructions De Montage Et D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27

Initial start-up

The heater is taken into operation by turning
the on/off-switch
ched on, the heater will be heating during 4
hours and cut off automatically.
The operating status „on" is shown by a
green LED.
The red LED is illuminated additionally while
the heater is heating up.
After the heating period of 4 hours the green
LED keeps on being illuminated and the red
LED is slowly blinking.
The on/off-switch must be turned to „0" to
disconnect the heater. The red and green
LED will go out.
WARNUNG!
Bedeckung verursacht Brandgefahr!
WARNUNG!
Nicht vorschriftsmäßig gefüllter
Steinkorb verursacht Brandgefahr!
3
3
thermostat
The sauna must heat up for approximate-
ly 45 minutes to achieve a typical sauna
climate.
The thermostat enables you to select the
temperature you desire within a range of
approx. 40° C to 110° C. Please remember,
however, that the sensors register only the
temperatures in their immediate vicinity.
Therefore, temperatures may differ in other
parts of the cabin. These differences are
typical for sauna climates, however.
The sauna heater is activated through a
clock timer with synchronous motor.
In consequence of the power frequency
(50 Hz) the synchronous motor is making
some noise.
This is not a fault or insufficiency of the
heater !
After it has been swit-
Kleinste Abstände vom Sauna-Heizgerät
zu brennbaren Baustoffen einhalten.
90 cm senkrecht zur Saunadecke
4 cm waagerecht zu den Saunawänden
25 cm senkrecht zum Saunaboden
0
on/off-switch
Indication
Is the bathing temperature not obtainable or
is the temperature different from the cabin
thermometer?
Please consider that the temperature sensor
is located in the area of the heating system.
The thermometer can be fi xed at different
places (f.ex. on the cabin wall above the
bench). The sensor can only feel the ambi-
ent temperature. A difference of 25 cms bet-
ween sensor and thermometer might cause
a difference in temperature upto 15°C.
Furthermore, many bimetal thermometers
react with delay, showing the real tempera-
ture after one hour only. If possible the ther-
mometer should not touch the cabin wall with
the hole rear side and should be mounted
with a space to reduce the response time.
It is absolutely possible that your thermome-
ter shows a lower value than it has been set
on the control box.

Troubleshooting

Oven doesn't work: Let check the microfuse
by an electrician.
The red LED is blinking quickly
Cause: Sensor and / or limiter is defective
Ask a specialist to check the sensor and
limiter.
The Limiter and the Sensor are located in the
sensor housing over the sauna oven
Limiter
0 Ohm = ok
= faulty
Sensor
An important value is the resistance at
normal room temperature. At 20°C, this is
about 1,9 kOhm
GB
23

Publicité

Table des Matières
loading

Table des Matières