Technical data
Voltage: 400 V AC 3N, 50 Hz
Power intake: 8,0 kW
Height: 880 mm when mounted 250 mm
above fl oor level
Width: 400 mm, depth: 255 mm
Stone capacity: 15 kg
Discharge current: max. 0.75 mA per kW of
heating output
Sauna heater for family saunas
When used for commercial purposes, the
sauna heater may only be used in combi-
nation with the rocker switch Type I Art. No.
94.4421.
The delivery package includes the follow-
ing components:
- sauna heater
- set of sauna stones, packed separately in
a fabric bag
- accessory bag, including:
1 cable connector assembly PG 13,5
4 tension-plate screws
- an oven-sensor board with overheat shu-
toff protection,
with sensor housing, two 3x25 mm fa-
stening screws and a 1,7 m long sensor
cable.
-grommet
-a replacement overheat protection module
Installation
The sauna heating unit is designed for ope-
ration with an input voltage of 400 V AC 3N
through the sauna control unit.
Minimum distances
The sauna cabin must have a minimum
inside height of 1.90 m
During installation of the sauna heating unit,
it is important to ensure that the vertical
distance between the upper surface of the
20
KTY-sensors
GB
sauna heating unit and the sauna cabin
ceiling is not less than 90 cm.
H e a t e r
s a f - e t y
grate
4 cm
40 cm
1. Tighten the 4 sheet metal screws to the
cabin wall according to the measurements
in fi g.3 and keep a 3 mms gap between
screw head and wall.
2. Connect the power cable as shown in the
circuit diagram . A circuit diagram is pro-
vided on the inside of the terminal box
cover.
3. Close the terminal box with the cover,
Fresh-air in-
let
cabin wall
25,5 cm
4 cm
4 cm
Fig. 1
3 mm
Fig. 2
Fig. 3