Installation Instructions for Iris® E-5 Series of Elements, All SF Options, All RAW Options
Incandescent Downlight Elements: E-5A19, E-5A19BB,
E-5P30 & E-5BB Series
Lock rotation of adjustable mechanism with thumbscrew.
Clip porcelain socket of M-120 power module to top of
element. For PAR30 lamps, reposition socket spring clip to
proper lamp location, see label. (Figure 4.) Element may
now be installed.
Low Voltage Downlight Elements: E-5MR Series
Appropriate power module must be installed which contains
lamp aiming mechanism and transformer. Lock horizontal
aiming of lamp. Rotate lamp tilt to a vertical position and
lock. Element may now be installed.
Fluoresecent Downlight Elements: E-5T & E-5TWB
Series
Lock rotation of adjustable mechanism with thumbscrew.
Attach socket of M-32T power module to top of element
with thumbscrews. Locate socket to proper lamp location,
see label. (Figure 5.) Element may now be installed.
Open Wall Wash Elements: E-5A19WW, E-5TWW &
E-5QT4WW Series
The dropped finger on the platform is rotated to the
wall which is to be washed and locked. (Figure 6.) Install
element as under downlight.
Adjustable Accent Elements: E-5PIN, E-5AA, E-5AA20,
E-5SLOT & E-5AABB Series
Appropriate power module must be installed which
contains lamp aiming mechanism and transformers (if
applicable). Rotate and lock horizontal aiming of lamp. The
dropped finger on the platform can be used as an aiming
aid, it points towards where the center beam is directed.
(Figure 7 .) Rotate lamp tilt and lock. For hot aiming a
screwdriver or pencil can be inserted, and used as a lever to
direct the lamp beam. Element may now be installed.
Side View of
E-5P30 Series
Figure 4.
2
PAR30 Long Neck
PAR30 Short Neck
Installation Instructions for Iris® E-5 Series of Elements, All SF Options, All RAW Options
701087
Lensed Wall Wash Elements: E-5LWW Series
Install Wall Wash mechanism into ceiling aperture. Ring is
keyed into platform by aligning notch in ring with dropped
finger on platform. Three springs on ring snap into notches
(Figure 7 .). The dropped finger on the platform is rotated to
the wall which is to be washed and lock with thumbscrew.
(Figure 6.)
Wall Wash Position
Figure 5.
Figure 6.
Dropped Finger
Figure 7.