Setting up
• Do not place the appliance in direct sunlight or near
cookers, radiators and similar sources of heat.
• The floor on which the appliance stands should be
horizontal and level. Compensate for uneven floors
with the adjustable feet.
Do not cover ventilation openings or
•
grille.
• Always install the appliance directly
against the wall.
• Well ventilated rooms
Important
When unpacking and setting up use protective gloves.
Appliance dimensions
A
B
TC 135 S 850 mm
600 mm
TC 175 S 1250 mm
600 mm
TC 255 S 1640 mm
600 mm
TC 445 S 1640 mm
750 mm
Installing beneath a worktop TC 135 S
For continuous worktops the refrigerator's tabletop can be detached.
The refrigerator can then be pushed under the existing worktop.
• To take off tabletop remove screws ➊.
• A cross-section of min. 200 cm
worktop for ventilation of the rear of the appliance.
TC 135 S / TC 175 S / TC 255 S / TC 445 S_3 11/2017
C
D
E
600 mm
648 mm 1153 mm
610 mm
650 mm 1180 mm
610 mm
650 mm 1180 mm
730 mm
850 mm 1410 mm
is re quired in the
2
Electrical connection
Only operate the appliance with alternating current (AC).
The permissible voltage and frequency are indicated on the type plate.
The socket must be properly earthed and protected by a fuse.
The tripping current of the fuse must be between 10 A and 16 A.
The socket must not be situated behind the appli-
ance and must be easily accessible.
Do not connect the appliance using an exten-
sion cable or extension socket.
Do not use stand-alone inverters (conversion of
direct current to alternating current/three-phase
current) or energy-saving plugs. Risk of damage
to the electronic control system!
Safety lock TC 135 S
The lock in the appliance door is equipped with a safety mechanism.
Locking the appliance
• Insert the key as shown
by arrow 1.
• Turn the key 90°.
To unlock the appliance, the
same procedure must be re-
peated in the same order.
Safety lock TC 175 S, TC 255 S, TC 445 S
The lock in the appliance door is
equipped with a safety mechanism.
Locking the appliance
• Insert the key as shown by
arrow 1.
• Turn the key 90°.
To unlock the appliance, the same
procedure must be repeated in the
same order.
Important
TC 135 S, TC 175 S, TC 255 S
The maximum load per grid shelf is 45 kg.
TC 445 S
The maximum load per grid shelf is 60 kg.
GB