Liquids used must be as thin as water. Thicker liquids will
not spray properly.
Do not overfill the tank.
NOTE: If using a measuring container or funnel to fill the
tank, be sure to thoroughly clean and rinse these items after
use. If premixing the spraying solution, rinse the container
used for mixing.
To fill:
Turn off the electrostatic function and remove the battery
from the unit.
Unscrew the cap and remove it from the tank.
Fill the tank with the desired liquid, up to 1/2 gal.
NOTE: To ensure proper operation of the sprayer, DO
NOT fill past the max fill line.
Screw the cap back onto the sprayer, making sure it is
tightened securely.
NOTE: Wipe the outside of the tank with a dry cloth and
clean up any spills before inserting the tank.
Reinstall the battery pack.
NOTICE:
It is important to thoroughly clean the unit after each use.
Allowing liquid to remain in an idle tool for an extended
period may cause its moving pieces and connectors to
seize up.
INSTALLING/REMOVING BATTERY PACK
See Figure 4.
WARNING:
Always remove battery pack from your tool when you are
assembling parts, making adjustments, cleaning, or when
not in use. Removing battery pack will prevent accidental
starting that could cause serious personal injury.
To install:
Align the grooves on the battery pack with the raised ribs
in the battery port and place the battery pack in the tool.
Make sure the latches on each side of the battery pack
snap in place and that the battery pack is secured in the
tool before beginning operation.
To remove:
Turn off the electrostatic function and remove the battery
from the unit.
Depress the latches on both sides of the battery pack to
release the battery pack and remove it from the tool.
For complete charging instructions, see the operator's manu-
als for your battery pack and charger.
OPERATION
Risk of fire or explosion. Spray area must be well-
ventilated and away from sparks or flames.
TURNING THE SPRAYER ON/OFF
See Figure 5.
To turn the sprayer ON, depress the switch trigger.
To turn the sprayer OFF, release the switch trigger.
NOTE: If the sprayer has trouble priming or won't spray when
the tank is filled, the pump has lost its prime. Turn the nozzle
selector dial to the largest micron setting. Once the spray is
even and consistent, release the switch trigger and rotate
the nozzle selector dial to the desired position.
USING THE ELECTROSTATIC FUNCTION
See Figure 6.
To activate electrostatic mode:
Press switch located on the bottom right side of the unit
to ON position.
To deactivate electrostatic mode:
Press switch located on the bottom right side of the unit
to OFF position.
USING THE 3-IN-1 ROTATING NOZZLE
See Figure 7.
There are three spray pattern settings located on the 3-in-1
rotating nozzle. To select a spray pattern, rotate the nozzle
selector to the desired spray pattern.
Low coverage – 65 microns (TX-1.5)
Medium coverage – 85 microns (TG-0.4)
High coverage – 160 microns (TG-1)
NOTE: If nozzles become clogged, see instructions in Main-
tenance section to clear blockage.
USING THE SPRAYER
See Figure 8.
Improper application of chemicals or solutions can result
in SEVERE INJURY or DEATH. Follow all CDC and EPA
guidelines. Follow the chemical manufacturer's safety
instructions and guidelines listed on the SDS sheet.
Install the battery pack into the tool.
Direct the sprayer nozzle directly at the surface areas you
wish to treat.
Depress the switch trigger to begin spraying.
Spray on a dry surface using long, even, overlapping
strokes.
8 — English
WARNING:
DANGER: