EN
7 Rollers
8 Safety switch, left
9 Vibration head
10 UV-C lamp (under the
cover)
11 UV-C lamp cover
12 Safety switch, right
13 Suction opening
14 Vibration button (under the
handle)
15 Dust fi lter
16 HEPA fi lter
Safety Devices
The device has two safety switches (8, 12). The UV-C lamp (10) only switches on if both
safety switches are pressed into the motor unit (3) (automatic switch-off function of the
UV-C lamp deactivated). This happens automatically when the device is placed on a fl at
surface. If the safety switches lose contact with the surface below, the automatic switch-
off function is activated and the UV-C lamp stops being lit.
Tips and Notes
•
Always clean mattresses on both sides.
•
We recommend cleaning new mattresses once a month. Older mattresses
should initially be cleaned every day for a week. We then recommend
cleaning them once a month.
•
The fi lters should be replaced every 12 – 18 months; the UV-C lamp (10)
should be replaced every 12 – 24 months. If you have any questions about
spare parts, please contact the customer service department via our web-
site: www.dspro.de/kundenservice
Use
PLEASE NOTE!
■
The device should only be used if it has been completely and correctly assembled!
The dust container and the fi lters must be inserted and must not be damaged.
If the dirt were to get inside the motor unit, this could damage the motor.
■
Make sure that the safety switches of the UV-C lamp are not blocked!
■
Always test the device fi rst on a small, inconspicuous spot.
1. Insert the mains plug into a properly installed plug socket that is easily accessible.
2. Place the device down fl at on the surface which is to be cleaned.
02243_DE-EN-FR-NL_A5_V2.1.indb 16
02243_DE-EN-FR-NL_A5_V2.1.indb 16
16
14
13
12
11
10
7
8
9
16
15
09.04.2019 16:32:43
09.04.2019 16:32:43