Canadian Certificate Of Conformity No: FM18CA0010X
l
= Status Outputs; 0 or 1
n
= Delta T control; 0 or 1
4496 212b2d2fgh0jkl0n0 TC-Standard+ X2 - Sample Gas Cooler (with 2 heat exchangers in
series)
b
= Gas cooler model: 1 or 2
d
= Supply voltage; 1, 2 or 4
f & g = Heat exchanger; 22, 27, 32 & 37
h
= Peristaltic Pumps; 0, 2, 4
j & k = Moisture detector / Filter; 00, 01,10, or 11
l
= Status Outputs; 0 or 1
n
= no value assigned.
4496 311 b2defghijklmno Thermoelectric Cooler, TC-MIDI + X2(fitted with 1 heat exchangers)
b
= Gas cooler types 1 or 2
d
= Supply Voltage; 1 or 2
e
= Gas paths; 1or 2
f,g = Heat exchangers; 60,61, 65, 66, 70, 75, 80 or 85
h
= Peristaltic pumps; 0, 2, or 4
i
= Sample gas pumps; 0, 1, 2, 6, or 7
j,k = Moisture detector / Filter; 00, 01, 02, 10, 11, 20 21, or 22
l,m = Status output; 00 or 10
n,o = Delta T control; 00 or 10
4496 312 b2d1fghijklm00 Thermoelectric Cooler, TC-MIDI + X2(fitted with 2 heat exchangers)
b
= Gas cooler types 1 or 2
d
= Supply Voltage; 1 or 2
f,g = Heat exchangers; 22, 27, 32, or 37
h
= Peristaltic pumps; 0, 2, or 4
i
= Sample gas pumps; 0, 1, 2, 6, or 7
j,k = Moisture detector / Filter; 00, 01, 02, 10, or 11
l,m = Status output; 00 or 10
4496 611a2c1efghijkl000 Thermoelectric Cooler, TC-Double X2
a
= Gas cooler types 1 or 2
c
= Voltage; 1 or 2
e,f
= Heat exchangers; 10,15, 20,25,30, or 35
g
= Peristaltic pumps; 0, 2, or 4
h
= Sample gas pumps; 0, 1, or 2
i,j
= Moisture Detector/Filter; 00, 01, 10, or 11
k,l
= Status output; 00 or 10
4496 611a2c1efghijkl000 Thermoelectric Cooler, TC-Double+ X2
a
= Gas cooler types 1 or 2
c
= Voltage; 1 or 2
e,f
= Heat exchangers; 22, 27, 32, or 37
g
= Peristaltic pumps; 0, 2, or 4
h
= Sample gas pumps; 0, 1, or 2
i,j
= Moisture Detector/Filter; 00, 01, 10, or 11
k,l
= Status output; 00 or 10
THIS CERTIFICATE MAY ONLY BE REPRODUCED IN ITS ENTIRETY AND WITHOUT CHANGE
FM Approvals LLC. 1151 Boston-Providence Turnpike, Norwood, MA 02062 USA
T: +1 (1) 781 762 4300 F: +1 (1) 781 762 9375 E-mail:
F 348 (Mar 16)
SCHEDULE
information@fmapprovals.com www.fmapprovals.com
Page 3 of 4