Electrical Requirements - Jenn-Air TC507 Guide D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Cutout dimensions
3"
(7.6 cm)
A
24" min.
(61 cm)
18" min.
(45.7 cm)
15
(38.7 cm)
A. Grounded electrical outlet must be a minimum of 3" (7.6 cm) away
from surrounding cabinets or nearby walls as shown. It can be
placed either to the left or the right side of the product.
Clearance dimensions
B
A. Leave 6" (15.2 cm) of clearance space to the right side of the
compactor in order to remove the compactor bags.
B. Leave 23" (58.4 cm) of clearance in front of the compactor in order
to fully open or remove the compactor drawer.
¹⁄₄
34
" min.
(87 cm)
¹⁄₄
" min.
A

Electrical Requirements

WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Recommended Grounding Method
This compactor is for use on a single phase, 115-volt, 60 Hz, AC
only 15- or 20-amp fused and properly grounded circuit and is
equipped with a grounding plug as shown below. It is
recommended that a separate circuit serving only this appliance
be provided.
This compactor must be grounded while in use to reduce the risk
of electric shock. The compactor is equipped with a three-
conductor cord and 3 prong grounding-type plug to fit the proper
grounding-type receptacle. The green (or green and yellow)
conductor in the cord is the grounding wire. Do not connect the
green (or green and yellow) wire to a live terminal.