Safety
®
CINDI
Basic is a safe toilet with several independent safety systems that prevent over-heating. If
the toilet becomes too hot, the current is automatically switched off. There are two different tempe-
rature gauges that monitor the temperature, two fuses that protect against overloading the electri-
cal circuit and over-heating protection that responds to abnormal temperatures inside the toilet.
Fuses
In the toilet appliance intake there are two fuses for incoming voltage. If necessary, these can be
checked / replaced by pulling out the fuse holder.
Included in the delivery are fuses for device input: Power in: 2 x 10 A
Change/control of fuses
If there is no voltage in the toilet, the fuses should be checked. Before doing this, the toilet must
be disconnected from the wall socket. On the back of the toilet there are two fuse holders which
contain a fuse of 10A each. Follow the steps below.
1. Pull out the cord from the wall.
2. Use a screwdriver to unscrew the cover of the fuse holder to open.
3. Pull out the cover in which the fuse is mounted.
4. When the lid has been removed, the fuse can be released. The picture below shows
the three parts that come with when
the lid is taken out of the toilet:
1. Lock: Screw in the fuse holder to hold the fuse in place
2. Fuse Adapter: For the fuse holder to function, the fuse must be inserted into the adapter.
3. Fuse: Check the fuse by studying the thread that is visible inside the fuse. About the thread
is damaged, bubbly or has gone off, the fuse must probably be replaced.
5. Put the old fuse back or repalce with a new one in the adapter and place it in the cover.
6. Screw the cover for the fuse holder back.