1 General
It describes a terrace liquefied gas lamp driven with liquefied gas (butane or propane).
Please follow the mounting instructions and the manual of the enclosed components
1.1 Part and structure
Transportable terrace liquefied gas lamp.
Housing: stainless steel.
Kroll GmbH, Wärme- und Lüftungstechnik,
71737 Kirchberg/Murr
880710
with tilt-controler + safety
device against tube rupture
1.2 Technical data
• Operation
with
(butane or propane): 50 mbar;
• Rated thermal load: 12,5 kW;
• Least setting:
• Consumption:
• Least consumption: 510g/hour
• Weight: approx.
1. Foundation
2. Gas container
3. Bracket
4. Hood
5. Running part
6. Inlet grid
7. Burner
8. Combustion chamber
9. Reflector
10. Gas valve
liquefied
gas
6.5 kW;
780g/hour
30 kilogram