If purchased as a complete system the unit will be wired to the terminal block.
However this should be considered to be a temporary connection to allow for
calibration and functional testing.
The cable shield should be connected to the enclosure and earth by way of an
EMC cable gland. The cable should be routed away from any high voltage cables
or electrically noisy equipment.
Any unused connections should be insulated such that they are a true no-connect.
Hydraulic Connection Details
The transducer is designed to be attached by the coupling thread only. Observe
the maximum torque of 27 Nm.
Model table / configuration
Model
Number
MPT016BB**
MPT040BB**
MPT100BB**
MPT250BB**
MPT400BB**
MPT600BB**
MPT1000BM**
MPT200PU**
MPT600PU**
MPT1K5PU**
MPT4K0PU**
MPT6K0PU**
MPT7K5PU**
MPT10K0PU**
Instruction for use
Having installed the transducer as instructed, they are ready to use. The transducer
should not be removed whilst the system is at pressure. Before applying the power,
check that the correct polarity and excitation levels are being supplied.
Maintenance and service
The transducer has no serviceable parts for repair or calibration please contact
Webtec Sales office.
Accessories
For panel meters (readouts) see DP130 bulletin.
For cables please contact Webtec sales office.
2
Outputs
Pressure
available range (Gauge)
5V, mA
16 bar
5V, mA
40 bar
5V, mA
100 bar
5V, mA
250 bar
5V, mA
400 bar
5V, mA
600 bar
5V, mA
1000 bar
5V, mA
200 psi
5V, mA
600 psi
5V, mA
1500 psi
5V, mA
4000 psi
5V, mA
6000 psi
5V, mA
7500 psi
5V, mA
10000 psi
Pressure Connection
1/4" BSPP
1/4" BSPP
1/4" BSPP
1/4" BSPP
1/4" BSPP
1/4" BSPP
M12 x 1.5
7/16" -20UN #4 SAE ORB Male
7/16" -20UN #4 SAE ORB Male
7/16" -20UN #4 SAE ORB Male
7/16" -20UN #4 SAE ORB Male
7/16" -20UN #4 SAE ORB Male
7/16" -20UN #4 SAE ORB Male
7/16" -20UN #4 SAE ORB Male