PIPE EXPANDING INSTRUCTIONS
Note: Improper pipe expanding is the main cause of refrigerant leakage. Follow the pipe
expansion steps below:
1. CUT THE PIPE
Confirm the pipe length according to the distance between the indoor unit and
outdoor unit.
Cut the required pipe with a pipe cutter.

2. REMOVE BURRS

Remove burrs with the shaper and prevent burrs from forming inside the pipe.
3. PLACE SUITABLE PIPE INSULATION
4. INSTALL THE UNION NUT
Remove the union nut on the indoor connection pipe and outdoor valve; install
the union nut on the pipe.
5. EXPAND THE PORT
Use the expander to open up the port
Expander
Hard mold
Pipe
pipe
pipe cutter
leaning
uneven
pipe
downwards
–21–
burr
shaper